talk-data.com talk-data.com

Topic

VMware

virtualization cloud_computing data_center

6

tagged

Activity Trend

12 peak/qtr
2020-Q1 2026-Q1

Activities

Showing filtered results

Filtering by: Jon Tate ×
IBM Storwize V7000, Spectrum Virtualize, HyperSwap, and VMware Implementation

IBM® Spectrum Virtualize Software Version 7.5 provides software-defined storage capabilities across various platforms, including IBM SAN Volume Controller, IBM Storwize® V7000, Storwize V7000 (Unified), Storwize V5000, Storwize V3700, and Storwize V3500. These offerings help clients reduce the complexities and cost of managing their storage in the following ways: Centralizing management of storage volumes to enable administrators to manage storage volumes from a single point Improving utilization of storage capacity with virtual volumes to enable businesses to tap into previously unused disk capacity Avoiding downtime for backups, maintenance, and upgrades Performing data migration without disruption to applications Enabling all storage devices to be organized into storage pools from which virtual volumes, whether standard, compressed, or thin-provisioned, are created with the characteristics that you want Delivering automation of storage management with SmartCloud Virtual Storage Center, IBM Tivoli® Storage Productivity Center (as applicable by platform), and IBM Tivoli Storage FlashCopy® Manager (as applicable by platform) Increasing the performance efficiency of storage pools with IBM Easy Tier® Restoring data access quickly with near and remote copy capabilities across Fibre Channel (FC), Fibre Channel over Ethernet (FCoE), and IP networks In this IBM Redbooks® publication, which is aimed at storage administrators and technical professionals, we describe the IBM HyperSwap® capability in IBM Spectrum™ Virtualize Software V7.5. HyperSwap delivers high availability (HA) and disaster recovery (DR) in one solution and reuses capital investments to achieve a range of recovery and management options that are transparent to host operations. This book describes how you can use HyperSwap with VMware to create an environment that can withstand robust workloads.

IBM Spectrum Virtualize and SAN Volume Controller Enhanced Stretched Cluster with VMware

This IBM® Redbooks® publication describes the IBM storage area network (SAN) and IBM Spectrum™ Virtualize, and SAN Volume Controller Enhanced Stretched Cluster configuration when combined with VMware. It describe guidelines, settings, and implementation steps necessary to achieve a satisfactory implementation. Business continuity and continuous availability of applications are among the top requirements for many organizations today. Advances in virtualization, storage, and networking make enhanced business continuity possible. Information technology solutions can now be designed to manage both planned and unplanned outages, and to take advantage of the flexibility, efficient use of resources, and cost savings that cloud computing offers. The IBM Enhanced Stretched Cluster design offers significant functions for maintaining business continuity in a VMware environment. You can dynamically move applications across data centers without interruption to those applications. The live application mobility across data centers relies on these products and technologies: IBM Spectrum Virtualize and SAN Volume Controller Enhanced Stretched Cluster Solution VMware Metro vMotion for live migration of virtual machines A Layer 2 IP Network and storage networking infrastructure for high-performance traffic management Data center interconnection

IBM SAN Volume Controller Enhanced Stretched Cluster with VMware

This IBM® Redbooks® publication describes the IBM storage area network (SAN) and IBM IBM System Storage® SAN Volume Controller enhanced stretched cluster solution VMware Metro vMotion for live migration of virtual machines A Layer 2 IP Network and storage networking infrastructure for high-performance traffic Data center interconnection

IBM SAN Solution Design Best Practices for VMware vSphere ESXi

In this IBM® Redbooks® publication, we describe recommendations based on an IBM b-type storage area network (SAN) environment that is utilizing VMware vSphere ESXi. We describe the hardware and software and the unique features that they bring to the marketplace. We then highlight those features and how they apply to the SAN environment, and the best practices for ensuring that you get the best out of your SAN. For background reading, we recommend the following Redbooks publications: - Introduction to Storage Area Networks and System Networking, SG24-5470 - IBM System Storage SAN Volume Controller Best Practices and Performance Guidelines, SG24-7521 - IBM System Storage SAN Volume Controller and Storwize V7000 Replication Family Services, SG24-7574 - Implementing the IBM System Storage SAN Volume Controller V6.3, SG24-7933 - IBM SAN Volume Controller Stretched Cluster with PowerVM and PowerHA, SG24-8142 - Implementing the IBM SAN Volume Controller and FlashSystem 820, SG24-8172 - IBM System Storage DS8000 Copy Services for Open Systems, SG24-6788 - IBM System Storage DS8000: Host Attachment and Interoperability, SG24-8887 This book is aimed at pre- and post-sales support, system administrators, and storage administrators.

IBM SAN and SVC Stretched Cluster and VMware Solution Implementation

This IBM® Redbooks® publication describes the IBM Storage Area Network and IBM SAN Volume Controller Stretched Cluster solution when combined with VMware. We describe guidelines, settings, and implementation steps necessary to achieve a satisfactory implementation. Business continuity and continuous application availability are among the top requirements for many organizations today. Advances in virtualization, storage, and networking have made enhanced business continuity possible. Information technology solutions can now be designed to manage both planned and unplanned outages, and the flexibility and cost efficiencies available from cloud computing models. IBM has designed a solution that offers significant functionality for maintaining business continuity in a VMware environment. This functionality provides the capability to dynamically move applications across data centers without interruption to those applications. The live application mobility across data centers relies on these products and technology: The industry-proven VMware Metro vMotion IBM System Storage® SAN Volume Controller Stretched Cluster solution A Layer 2 IP Network and storage networking infrastructure for high performance traffic management

IBM System Storage SAN Volume Controller and Storwize V7000 Replication Family Services

This IBM® Redbooks® publication describes the new features that have been added with the release of the IBM System Storage® SAN Volume Controller (SVC) and IBM System Storage Storwize® V7000 6.4.0 code, including Replication Family Services. Replication Family Services refers to the various copy services available on the SVC and Storwize V7000 including IBM FlashCopy®, Metro Mirror and Global Mirror, Global Mirror with Change Volumes, Volume Mirroring, and Stretched Cluster Volume Mirroring. The details behind the theory and practice of these services are examined, and SAN design suggestions and troubleshooting tips are provided. Planning requirements, automating copy services processed, and fabric design are explained. Multiple examples including implementation and server integration are included, along with a discussion of software solutions and services that are based on Replication Family Services. This book is intended for use by pre-sales and post-sales support, and storage administrators. Readers are expected to have an advanced knowledge of the SVC, Storwize V7000, and the SAN environment. The following publications are useful resources that provide background information: Implementing the IBM System Storage SAN Volume Controller V6.3, SG24-7933 Implementing the IBM Storwize V7000 V6.3, SG24-7938 IBM SAN Volume Controller and Brocade Disaster Recovery Solutions for VMware, REDP-4626[ IBM System Storage SAN Volume Controller Upgrade Path from Version 4.3.1 to 6.1, REDP-4716[ Real-time Compression in SAN Volume Controller and Storwize V7000, REDP-4859 SAN Volume Controller: Best Practices and Performance Guidelines, SG24-7521 Implementing the Storwize V7000 and the IBM System Storage SAN32B-E4 Encryption Switch, SG24-7977